  1.     SECTION 10815
  2.  
  3.     BABY ACCESSORIES FOR TOILET ROOMS
  4.  
  5. NOTE ** This section includes three types of baby changing stations and a child protection seat for installation in public restrooms and fitting rooms.
  6. NOTE ** 
  7. NOTE ** These accessories are made by Koala Corporation, located at:
  8. NOTE **      11600 E. 53rd Ave.
  9. NOTE **      Unit D
  10. NOTE **      Denver CO 80239-2312
  11. NOTE **      Tel:  (303) 574-1000
  12. NOTE **      Fax:  (303) 574-9000
  13. NOTE ** 
  14. NOTE ** Koala baby changing stations and child protection seat are made of high impact polyethylene or stainless steel, are designed to be surface mounted, and fold out of the way when not in use.
  15. NOTE ** 
  16. NOTE ** SECTION 10815 - BABY ACCESSORIES FOR TOILET ROOMS, Copyright 1998, The Architect's Catalog, Inc.
  17.  
  18. PART 1  GENERAL
  19.  
  20. 1.1    SECTION INCLUDES
  21.  
  22.     A.    Horizontal design baby changing stations.
  23.  
  24.     B.    Vertical design baby changing stations.
  25.  
  26.     C.    Counter-top design baby changing stations.
  27.  
  28.     D.    Child protection seats.
  29.  
  30.     E.    Metal restroom door signs.
  31.  
  32. 1.2    RELATED SECTIONS
  33. NOTE ** Coordinate the sections listed below with actual project requirements.
  34.  
  35.     A.    Section 06100 - Rough Carpentry:  Wood stud framing for support of accessories.
  36.  
  37.     B.    Section 09260 - Gypsum Board Assemblies:  Metal stud framing for support of accessories.
  38.  
  39.     C.    Section 10160 - Metal Toilet Compartments.
  40.  
  41.     D.    Section 10165 - Plastic Laminate Toilet Compartments.
  42.  
  43.     E.    Section 10170 - Plastic Toilet Compartments.
  44.  
  45. 1.3    REFERENCES
  46.  
  47.     A.    ADA; Americans with Disabilities Act; Federal Register,  Volume 56, No, 144 28 CFR part 36.
  48.  
  49.     B.    ANSI A117.1 - Safety Standards for the Handicapped.
  50.  
  51.     C.    ASTM G 21 - Determining Resistance of Synthetic Polymeric Materials to Fungi.
  52.  
  53.     D.    ASTM G 22 - Determining Resistance of Plastics to Bacteria.
  54.  
  55.     E.    California OSHPD R-0367 for Hospital Installation.
  56.  
  57. 1.4    SUBMITTALS
  58.  
  59.     A.    Submit under provisions of Section 01300.
  60.  
  61.     B.    Product Data:  Submit manufacturer's complete product data, including information on compliance with governing regulations.
  62.  
  63.     C.    Installation Instructions:  Indicate special procedures for various substrate conditions and dimensional data for compliance with ADA and ANSI A117.1 regulations.
  64.  
  65. 1.5    FIELD MEASUREMENTS
  66.  
  67.     A.    Verify locations of supporting structure are in compliance with manufacturer's requirements.
  68.  
  69. 1.6    WARRANTY
  70.  
  71.     A.    Submit manufacturer's limited five-year warranty on materials and workmanship.
  72.  
  73.     B.    Include one-year replacement warranty against vandalism or natural disaster.
  74.  
  75.  
  76. PART 2  PRODUCTS
  77.  
  78. 2.1    MANUFACTURER
  79.  
  80.     A.    Provide products manufactured by Koala Corporation; 11600 E. 53rd Ave., Unit D, Denver CO 80239-2312. ASD. Tel: (303) 574-1000; Fax: (303) 574-9000.
  81.  
  82.     B.    Substitutions not permitted.
  83.  
  84. 2.2    BABY CHANGING STATIONS
  85. NOTE ** Coordinate materials listed below with project requirements.
  86.  
  87.     A.    Materials:  Molded high impact polyethylene, reinforced with steel-on-steel hinges and 10-gage steel mounting supports; gas shock mechanism designed to lift door from open position and brake to prevent trapping fingers.
  88.  
  89.     B.    Materials:  16-gage Type 304 stainless steel, architectural satin finish, reinforced with steel-on-steel hinges and 10-gage steel mounting supports; gas shock mechanism designed to lift door from open position and brake to prevent trapping fingers.
  90. NOTE ** Koala Bear Kare Baby Changing Stations delight parents and protect children. Select one or more of the following styles for installation in public restrooms for both sexes.  
  91. NOTE ** 
  92. NOTE ** The horizontal design was created for areas with narrow passageways.  It extends no more than four inches from wall when closed and only 20 inches when opened.  
  93. NOTE ** 
  94. NOTE ** The vertical design requires only 22 inches of horizontal wall space and can be mounted over the commode or in the wash area.  
  95. NOTE ** 
  96. NOTE ** Factory-installed locks to secure stations from vandalism are optional.
  97.  
  98.     C.    Horizontal Design.
  99.         1.    Provide unit engineered to withstand loads of up to 350 pounds.  Provide door that lowers to form concave changing platform, equipped with child protection straps and snap lock fasteners.  
  100.         2.    Provide integrated dispenser for chemical-free, biodegradable sanitary bed liners.
  101.         3.    Provide permanently mounted, graphic instructions and safety messages in English and five other languages.
  102.         4.    Provide factory-installed locks and two keys for each unit.
  103.  
  104.     D.    Vertical Design.
  105.         1.    Provide unit engineered to withstand loads of up to 350 pounds.  Provide door that lowers to form concave changing platform, equipped with child protection straps and snap lock fasteners.
  106.         2.    Provide integrated dispenser for chemical-free, biodegradable sanitary bed liners.
  107.         3.    Provide permanently mounted, graphic instructions and safety messages in English and five other languages.
  108.         4.    Provide factory-installed locks and two keys for each unit.
  109.         
  110.     E.    Stainless Steel Recessed Mounted Horizontal Design.
  111.         1.    Provide unit engineered to withstand loads of up to 350 pounds.  Provide door that lowers to form concave changing platform, equipped with child protection straps and snap lock fasteners.  
  112.         2.    Provide integrated dispenser for chemical-free, biodegradable sanitary bed liners.
  113.         3.    Provide permanently mounted, graphic instructions and safety messages in English and five other languages.
  114.         4.    Provide factory-installed locks and two keys for each unit.
  115.  
  116.     F.    Stainless Steel Surface Mounted Vertical Design.
  117.         1.    Provide unit engineered to withstand loads of up to 350 pounds.  Provide door that lowers to form concave changing platform, equipped with child protection straps and snap lock fasteners.
  118.         2.    Provide integrated dispenser for chemical-free, biodegradable sanitary bed liners.
  119.         3.    Provide permanently mounted, graphic instructions and safety messages in English and five other languages.
  120.         4.    Provide factory-installed locks and two keys for each unit.
  121.         
  122.     G.    Counter-Top Recessed Mounted Design.
  123.         1.    Provide unit engineered to withstand loads of up to 350 pounds.  Provide door that lowers to form concave changing platform, equipped with child protection straps and snap lock fasteners.  
  124.         2.    Provide integrated dispenser for chemical-free, biodegradable sanitary bed liners.
  125.         3.    Provide permanently mounted, graphic instructions and safety messages in English and five other languages.
  126.         4.    Provide factory-installed locks and two keys for each unit.
  127.  
  128.     H.    Counter-Top Surface Mounted Top Design.
  129.         1.    Provide unit engineered to withstand loads of up to 350 pounds.  Provide door that lowers to form concave changing platform, equipped with child protection straps and snap lock fasteners.
  130.         2.    Provide integrated dispenser for chemical-free, biodegradable sanitary bed liners.
  131.         3.    Provide permanently mounted, graphic instructions and safety messages in English and five other languages.
  132.         4.    Provide factory-installed locks and two keys for each unit.
  133.         
  134. 2.3    CHILD PROTECTION SEATS
  135. NOTE ** The Koala Bear Kare Child Protection seat provides peace of mind for parents by allowing them to seat their baby safely in the restroom stall or fitting room with them.  The compact design fits into the smallest stalls, extending less than 6 inches when the seat is folded closed.  Coordinate materials listed below with project requirements
  136.  
  137.     A.    Materials:  Molded high impact polyethylene.
  138.  
  139.     B.    Materials:  16-gage Type 304 stainless steel.
  140.  
  141.     C.    Design:  Provide folding seat engineered to withstand static load of up to 150 pounds, with seat and back concave molded and tilted backward slightly for safety.  Equip seat with child protection straps and snap lock fasteners.
  142.  
  143. 2.4    ACCESSORIES
  144.  
  145.     A.    Fasteners:  Provide each baby accessory with all hardware required for secure installation to various substrates.
  146.  
  147.     B.    Signs:  Provide metal sign for installation on restroom door with each baby accessory.
  148.  
  149.  
  150. PART 3  EXECUTION
  151.  
  152. 3.1    EXAMINATION
  153.  
  154.     A.    Verify that site conditions are ready to receive accessories and dimensions are in compliance with manufacturer's instructions.
  155.  
  156.     B.    Verify that all components necessary for proper installation are available.
  157.  
  158. 3.2    INSTALLATION
  159.  
  160.     A.    Comply with manufacturer's printed instructions, except where more stringent requirements are mandated by governing authorities, and except where project conditions require extra precautions or provisions.
  161.  
  162.     B.    Locate baby changing stations and child protection seats to eliminate interference with door swings or use of fixtures in compliance with ADA compliance.
  163. NOTE ** Edit paragraphs below to conform to project conditions.
  164.  
  165.     C.    At stud walls, verify that at least one side of changing station is located so fasteners will be installed directly into stud.  If stud spacing is other than 16 inches on center, use toggles for installation at opposite side.
  166.  
  167.     D.    At solid masonry walls, drill pilot holes for installation of expansion-type fasteners. 
  168.  
  169.     E.    At toilet partitions, use through-bolt fasteners for installation of child protection seat.
  170.  
  171.     F.    Install metal sign on restroom door, using double-stick tape or corrosion-resistant screws.
  172.  
  173. 3.3    CLEANING AND ADJUSTING
  174.  
  175.     A.    Upon completion of installation, clean all surfaces that have become soiled during installation.
  176.  
  177.     B.    Fill built-in dispenser in baby changing stations with sanitary bed liners.
  178.  
  179.  
  180.     END OF SECTION